Any single zone or any combinations of zones can be

configured to release

Configurable first stage sounder delays

Configurable detection delays

Zero time delay upon manual release option

Compatible with I.S. barriers

Non-latching zone input option to receive signals from

other systems such as aspirating equipment

Countdown timer shows time remaining until release

Supports up to seven, four-wire status indicators

Configurable extinguishant delays up to 60

seconds in 5 second steps

Configurable extinguishant duration up to 5

minutes in 5 second steps

Supports up to seven, four wire status indicators

Built in Extract Fan control

Approved and certified to EN12094-1, EN54-2

and EN54-4

 

UL864 and FM Listed

Three initiation circuits as standard

Any single zone or any combinations of zones can be

configured to release

Configurable first stage NAC delays

Configurable detection delays

Zero time delay upon manual release option

Supports up to seven, four wire status indicators

Built in Extract Fan control

Compatible with I.S. barriers

Non-latching zone input option to receive signals from

other systems such as aspirating equipment

Configurable releasing delays up to 60 seconds in 5

second stops

Configurable releasing duration up to 5 minutes in 5

second steps.

Countdown timer shows time remaining until

release

Approved to EN12094-1, EN54-2 and EN54-4

16 detection zones

Up to 4 extinguishant areas

Dual extinguishant outputs for each area (configurable as

Main/Reserve)

First and second stage sounder outputs for each area

First and second stage volt free changeover contacts for

each ara

Released volt free contact per area

Fault volt free contact per area

Programmable extinguishant delay

Programmable output duration

Countdown indicator shows time until release in

seconds

Mode select and manual release controls per area

Monitored remote manual release input

Monitored remote hold input

Monitored remote mode select (door interlock)

input

Monitored remote released pressure switch input

Monitored Abort input

Serial connections for Sigma Si status units and

ancillary boards. (K588)

Single area extinguishing panel

Dual extinguishing outputs with main/reserve configuration option

Secure Event logging 1000 events

Dynamic LCD Display

4 configurable user passcodes

Compatible with I.S. barriers

6 x Programmable relay outputs

Countdown timer displays time remaining until release

Supports up to seven, Sigma ZXT four-wire status indicators (also

compatible with Sigma SI status units for retrofit applications)

Larger enclosure available with option of 2.6A or 5.25A PSU

Approved and certified to EN12094-1, EN54-2 and EN54-4

Compatible with LE2 configuration software

Approved by LPCB to EN54-2

EN54-4 & EN54 Part 13

VdS approved

UL & FM

Supports Apollo & Hochiki

loop protocols

Supports K-Mesh wireless

2-8 and 2-16 loop variants

Loop current – 500mA per loop

Individual loop learn option

Over 6000 sub address points

per panel

Up to 2000 software zones

48, 96 or 144 Zonal LED options

False Alarm

management features

Large colour touch

screen display

Automatic LCD backlight control

Up to 5000 programmable cause

and effect rules per

Taktis system

Up to 24 Configurable

function buttons

Three programmable

non-monitored inputs

5 Programmable Relay Outputs

Four programmable sounder

circuits each, rated at 2.5A

Up to 512 programmable inputs/

outputs can be provided using

plug-in or serially connected

option cards

Option to ‘invert’

input/output operation

Network of up to 127 panels*

Fire and fault routing

inputs and outputs

Config upload/download

via USB flash drive or PC

running LE2 software

10,000 entry downloadable

event log

Optional Media Gateway

communications card

5.25A or 10.25 integral power

supply options

Battery capacity 26Ah or 45Ah

dependent on enclosure size

Syncro AS Features

Expandable from one to two loops*

Network up to 64 panels*

Two programmable sounder circuits

Five programmable inputs

Three programmable relays

3A power supply

Up to 512 additional programmable I/O via

Syncro I/O modules*

Powerful, network-wide cause and effects*

Sensitivity adjustment and drift compensation

Compatible with View repeaters*

Supports Apollo, Argus Vega and Hochiki protocols

Stores 500 last events in event log

Installer friendly, removable equipment chassis

Different language and character set variants available

Approved and certified to EN54-2/EN54-4